Products

  • GDP-311MIX SF6/N2 Mixed Gas Purity Analyzer

    GDP-311MIX SF6/N2 Mixed Gas Purity Analyzer

    The GDP-311MIX SF6/N2 mixed gas purity analyzer integrates SF6 purity testing and O2 testing. With one on-site measurement, all indicators can be tested, greatly saving gas in the equipment, reducing user workload, and improving work efficiency.

    The GDP-311MIX SF6/N2 mixed gas purity analyzer adopts the best sensors; The purity of SF6 gas adopts a stable and reliable German Smart Gas NDIR principle sensor, and oxygen testing uses a British CITY electrochemical sensor. Color LCD display, real-time display of various parameters, foolproof operation throughout the process, built-in rechargeable battery, dual-use for AC and DC.

  • GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.

  • GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions.

    The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point.

    Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation.

    GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device.

  • GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry. 

     

  • GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC is ideal instrument when it is necessary to test water content of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument

     

  • GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. 

  • GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. 

  • GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration.

  • GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission,  SF6 gas electrical switch manufacturing plant and other departments.

     

  • GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time.

  • GDFJ-311M SF6 Gas Decomposition Product Tester

    GDFJ-311M SF6 Gas Decomposition Product Tester

    GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product.

  • GDP-311IR SF6 Gas Purity Tester (IR Method)

    GDP-311IR SF6 Gas Purity Tester (IR Method)

    GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. 

Send your message to us:

Write your message here and send it to us